1. SELF TEST:
Self test each time switched on.
When UPS is turned on, it makes self-test to provide a reliable operation and prevent any damage caused.
Auto self-test and discharge protection.
2. DC START CAPABILITY:
The UPS can be activated without utility power.
3. UPS POWER SUPPLIED OUTLETS:
Line-Interactive UPS+AVR
Allows 75% to 125% input voltage range-best protection for computer equipment.
With AVR function (boost & buck), UPS provides a stable power to the loads as the input voltage fluctuates.
4. ELECTRICAL PROTECTION:
Automatic cut off on short circuit or Input Circuit Breaker. If UPS is overload, this circuit breaker will trip to disconnect the unit from utility power. Then the black button will pop up, and none of the surge protection outlets will provide power. Unplug at least one piece of equipment, and reset the Circuit breaker by pressing the button back into place.
5. MODEM/NETWORK PROTECTION:
RJ45 JACK ; Simultaneous protection for network, telephone, fax & modem.
6. AUDIBLE ALARM:
7. INTERFACE AND SOFTWARE:
USB Interface.
Software For MS-Windows 98/NT/ME /2000
RS-232 Interface.
Software For MS-Windows 98/NT/ME /2000, Novell, Linux
8. CPU MICRO PROCESS CONTROL, USE WITH STABILITY.
9. GREEN FUNCTION:
If the battery is discharging under no load, will shut down automatically to keep the span life of battery
10. BATT FAULT: Red LED Display
MT-800/1000/1500/2000 Specification
MODEL |
MT – |
MT – |
MT – 1500 |
MT-2000 |
VA/WATTS |
800VA/480W |
1000VA/600W |
1500VA/840W |
2000VA1000W |
|
110V (80V~140V) / 220V (160V~280V) |
|||
INPUT FREQUENCE |
50 OR 60 ± 3HZ |
|||
(AVR) |
110V OUT: 100V-120V 220V OUT: 200V-240V |
|||
OUTPUT VOLTS ON |
110VAC ±10% / 220VAC ±10% |
|||
OUTPUT FREQUENCE ON |
50 OR 60 ± 1HZ |
|||
|
10 ~ 40MIN |
|||
|
1*12V 1234w |
2*12V7AH |
2* 12V1234w |
2*12V1234W |
Typical |
RATED 4HRS TO 90% OF FULL CAPACITY |
|||
|
AUTO SELF-TEST AND DISCHARGE PROTECTION |
|||
SELF TEST |
SELF TEST EACH TIME SWITCHED ON |
|||
TRANSFER TIME |
2~4 ms |
|||
OUTLETS |
|
|||
AUDIBLE ALARM |
|
|||
INDICATORS |
GREEN LED ON-LINE. BACK UP SLASH RED LED OVERLOAD: |
|||
INTERFACE |
RS-232 or USB |
|||
ENVIRONMENT |
AMBIENT OPERATING: 0 |
|||
AUDIBLE NOISE |
<40DBA (1-METER FROM SURFACE) |
|||
DC START |
YES |
|||
SURGE ENVEGY RATING |
240 JOULES |
|||
OVERLOAD |
BACK UP MODE 100% SHUT DOWN. IN AC MODE 110% ALARMS (NO SHUT DOWN) |
|||
ELECTRICAL PROTECTION |
AUTOMATIC CUT OFF ON SHORT CIRCUIT AND INPUT CIRCUIT fuse. |
|||
MODEM / NETWORK PROTECTION |
RJ45(8WIRE) ONE IN → ONE OUT OPATION FOR MODEN OR NETWORK |
|||
CONFORMANCE |
APPLICABLE |
|||
SOFTWARE (SUPPEORT) |
OPTION |
|||
DIMENSIONS(mm) L x W x H |
310*110*170 |
|||
NET WEIGHT |
8.KGS |
12 KGS |
13KGS |
15KGS |